Skip to content

Collect machine data locally with Qynetic Edge

Qynetic Edge reads machine signals on the factory network, stores mapped events locally and forwards them to Qynetic over an outbound HTTPS connection.

Start at the machine

An installation can begin offline. Choose the machine and its interface, then identify the signals you need. For a first OEE connection, that might be the operating state and a completed-part counter. In the local interface you can compare the incoming values with the operator panel and see which observations became events.

Each adapter needs a different kind of address. An OPC UA server exposes nodes, an MTConnect agent exposes data items, an MQTT broker carries messages on topics, and Modbus TCP devices expose bits and registers. For Citizen L12 and L20E lathes with a MELDAS M70 control, Edge also includes a dedicated read-only CE adapter.

What should site IT allow?

List the exact address and port of each machine endpoint. For cloud delivery, Edge initiates HTTPS to the Qynetic origin specified in its connection configuration, normally on TCP 443. If the site uses a proxy, test from the Edge process itself. Opening Qynetic in a browser checks the browser’s access only.

What happens when the cloud connection drops?

Edge keeps committed events in a persistent local queue. Once the connection returns, it sends them with their original event identifiers so that retries can be recognised. Local collection can continue while the machine is reachable and disk space is available. When storage reaches its limit, collection pauses.

At commissioning, register the Edge installation and match each machine’s external ID to the correct site. Check that Qynetic accepts the queued events as well as receiving the device heartbeat. These checks tell you whether both the connection and the machine mapping are working.

Follow one finished part

A mill has counted 40 parts. Follow the next one through a connection loss and a retry.

Machine counter
40
Events queued on Edge
0
Parts added in Qynetic
0

Edge takes 40 as the starting value. The first reading establishes a baseline for this counter.

Book a call about your factory

Tell us what you make and which machines you run, and we will walk through how Qynetic fits. If you would rather get news and early access, join the waitlist.